Siemens Solid State Starter
Length = 12″ , Width = 12″, Depth = 9″
Starter sizing is based on 80 starts/hr. If 120 starts/hr is required, you must bump up one size.
In Delta Configuration
Power | Siemens | |||
---|---|---|---|---|
HP | Volts | FLA | Overload Range | MEI Part # |
10 | 208 | 32 | 14 – 52 amps | 300-7234-042 |
240 | 28 | 14 – 52 amps | 300-7234-042 | |
480 | 14 | 14 – 52 amps | 300-7234-042 | |
15 | 208 | 48 | 18 – 68 amps | 300-7234-055 |
240 | 42 | 14 – 52 amps | 300-7234-042 | |
480 | 21 | 14 – 52 amps | 300-7234-042 | |
20 | 208 | 62 | 22 – 85 amps | 300-7234-068 |
240 | 54 | 18 – 68 amps | 300-7234-055 | |
480 | 27 | 14 – 52 amps | 300-7234-042 | |
25 | 208 | 78 | 26 – 100 amps | 300-7234-080 |
240 | 68 | 22 – 85 amps | 300-7234-068 | |
480 | 34 | 14 – 52 amps | 300-7234-042 | |
30 | 208 | 92 | 34 – 131 amps | 300-7234-105 |
240 | 80 | 26 – 100 amps | 300-7234-080 | |
480 | 40 | 14 – 52 amps | 300-7234-042 | |
575 | 35 | 12 – 44 amps | 300-7235-035 | |
40 | 208 | 120 | 43 – 162 amps | 300-7234-130 |
240 | 104 | 34 – 131 amps | 300-7234-105 | |
480 | 52 | 18 – 68 amps | 300-7234-055 | |
575 | 42 | 14 – 52 amps | 300-7235-042 | |
50 | 208 | 150 | 51 – 195 amps | 300-7234-157 |
240 | 130 | 43 – 162 amps | 300-7234-130 | |
480 | 65 | 22 – 85 amps | 300-7234-068 | |
575 | 55 | 18 – 68 amps | 300-7235-055 | |
60 | 208 | 177 | 83 – 315 amps | 300-7234-252 |
240 | 154 | 51 – 195 amps | 300-7234-157 | |
480 | 77 | 26 – 100 amps | 300-7234-080 | |
575 | 68 | 22 – 85 amps | 300-7235-068 | |
75 | 208 | 221 | 83 – 315 amps | 300-7234-252 |
240 | 192 | 83 – 315 amps | 300-7234-252 | |
480 | 96 | 34 – 131 amps | 300-7234-105 | |
575 | 80 | 26 – 100 amps | 300-7235-080 | |
100 | 480 | 124 | 43 – 162 amps | 300-7234-130 |
575 | 105 | 35 – 131 amps | 300-7235-105 | |
125 | 480 | 157 | 51 – 195 amps | 300-7234-157 |